Concrete Moisture Problems

Static control floors should never be installed without first testing your concrete slab for possible moisture and alkalinity problems. Up front testing can prevent future problems and shutdowns due to failed flooring installations.

Moisture curling of flooring tile.

Picture of curling tiles due to moisture problems in concrete (courtesy of Donnelly Inspections)

Did you know that the number one cause of ESD flooring installation failures is moisture permeation through concrete slabs from below the sub-floor? Moisture vapor, inside concrete, becomes alkaline – adversely reacting with flooring adhesives and consequently compromising the bond you expect from adhesives. More importantly, this problem is almost always unexpected because it rarely involves ground water, heavy rains or the local water table – so there are no visual predictors. The problem isn’t solved by installing drains or water diverters around a building because it isn’t the result of weather. It is the result of evaporation of water from far below the surface and the worst problems are where you would expect them the least: desert and arid climates like California, Arizona, Colorado, Utah, Texas and Nevada. But the problem also haunts many other locations so it’s always a necessity to learn about moisture and how to test for it before it ruins your new anti static or conductive flooring installation.

And, if you’re a flooring professional – you’re expected to know about moisture problems because your client certainly doesn’t know about it…..

This page contains some information and helpful links to help you get up to speed on this problem.

Helpful links to learn more about hydrostatic pressure, osmotic blisters, vapor emissions and moisture vapor problems installing Resilient and Epoxy Flooring:

Moisture testing kit

ASTM F1869 Moisture Test Kit

Here’s ASTM’s own description of a resilient floor:


Resilient Flooring — It would be helpful to start with the definition of this category of flooring products, because this term is becoming more commonly used. According to F 141, resilient flooring is an organic floor surfacing material made in sheet or tile form or formed in place as a seamless material of which the wearing surface is non-textile. The resilient floor covering classification by common usage includes, but is not limited to asphalt, cork, linoleum, rubber, vinyl, vinyl composition and polymeric poured seamless floors. Resilient in this sense is used as a commonly accepted term, but does not necessarily define a physical property.

 

Pertinent Articles

 

Antistatc flooring home
Get Adobe PDF Reader
Moisture ESD Flooring Studies

Get It!


Avoiding Flooring Failure—
Insist on Moisture Testing

by Terry Nali, Coordinator
INSTALL Twin Cities and IFMA MSP Member

http://mcmorrowreport.com/articles/floorfail.asp

New window


Reducing Bond Failures Caused by Moisture Vapor Transmission
By: Robert R. Cain
http://www.concretenetwork.com/bob_cain/

New window


Vapor Barriers under Concrete Floor Slabs: Friend or Foe?
by Steve Ragan
Graniterock
http://www.graniterock.com/tnvaporbarriers.html

New window


A GUIDE TO FLOOR MOISTURE PROBLEMS
By Loss Mitigation Services Inc.
www.lmsrestoration.com

New window


An excellent PowerPoint visual presentation on Moisture Problems
by B. Lee Lawrence, P.E.
Wiss, Janney, Elstner Associates, Inc.
13581 Pond Springs Road, Suite 107
Austin, Texas:
http://www.foundationperformance.org/pastpresentations/
LawrencePres_18Aug04.pdf

New window


Testing for Moisture:
Designation: F 2170 – 02
Standard Test Method for
Determining Relative Humidity in Concrete Floor Slabs
Using in situ Probes1
This standard is issued under the fixed designation F 2170; the number immediately following the designation indicates the year of Original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.
Link to ASTM site to purchase: Standard F2170-02

New window


ASTM F1869 - 04 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride
Link to purchase this ASTM standard F1869 - 04

New window


Calcium Chloride v. In-situ Relative Humidity
Which moisture test method is better? Here’s what one moisture expert has to say.

http://www.moisturetesting.com/
calcium_chloride_vs__in-situ_relative_humidity.htm

New window


An informative article by Peter Craig and George Donnelly about the hazards of improper ASTM concrete moisture/vapor testing and the pitfalls of relying on just one type of ASTM test method.

Moisture Testing of Concrete Slabs – When 3 pounds is not 3 pounds:  5 Reasons why moisture testing of concrete fails to reveal a moisture problem

  1. Curing, sealing, or bondbreaking compounds

  2. Adhesive residue from previous flooring

  3. HVAC system operation

  4. Redistribution of moisture

  5. Below-slab vapor retarder

Read their article at this link
http://www.moisturetesting.com/
When%203%20lbs%20is%20not%203%20lbs.pdf

New window

Vapor barriers: nuisance or necessity?
Where a moisture-sensitive floor covering or coating is...
By Craig, Peter A.
Publication: Concrete Construction
Date: Monday, March 1 2004
http://www.allbusiness.com/manufacturing/
nonmetallic-mineral-product-manufacturing/768681-1.html

New window

 

American Moisture Test Kit - Instruction Guide
http://americanmoisturetest.com/technical1.htm

New window

The following standards can be found at www.ASTM.org

ASTM F2170-03
Standard Test Method for
Determining Relative Humidity in Concrete Floor Slabs
Using in situ Probes1

Link to ASTM site to purchase: ASTM Standard F2170-02

New window

ASTM F1869 - 04 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride
Link to purchase this ASTM standard F1869 - 04

New window

Historical Standard ASTM E1907 – 04 Standard Guide to Methods of Evaluating Moisture Conditions of Concrete Floors to Receive Resilient Floor Coverings

Link to purchase ASTM E 1907 – 04

This guide includes both quantitative and qualitative procedures used to determine the amount of water or water vapor present in or emitting from concrete slabs and criteria for evaluating the moisture-related acceptability of concrete slabs to receive resilient floor coverings and related adhesives.

New window

ASTM D4263 - 83(2005)  Standard Test Method for Indicating Moisture in Concrete by the Plastic Sheet Method

Link to purchase ASTM Standard D4263-83(2005)

New window

Why are We Still Having Problems with Moisture?

Good practices and excellent products are only the beginning to the solution

By Howard Kanare

Water is an essential ingredient in concrete, but uncontrolled excessive moisture can create a whole host of problems with concrete floor slabs. Some of the modes of distress include:

  • Adhesive breakdown of adhered finish floor coverings
  • Debonding of coatings
  • Osmotic blisters of epoxy systems including coatings and epoxy terrazzo
  • High pH (alkali) attack of floor finishes
  • Microbial growths
  • Flooring expansion, such as cupping of wood strips or planks
  • Reactions between incompatible floor patching/leveling materials

Read the full article at Concrete Construction Online