StaticWorx Walking Test Kit System

Measure, record, analyze and report electrostatic voltage generation and decay performance on:

Features

The PGA-710B is a unique electrostatic data analysis device for use with the PFK-100 Fieldmeter/Charge Plate Monitor Set. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions. Its analytical features document and automatically calculate projected levels of typical Human Body (HBM) voltages. It helps determine the risk of equaling or exceeding damaging or hazardous HBM discharge voltages in static sensitive facilities.

The Autoanalyzer links to a Field meter’s analog output and lap top computer’s USB using provided cables. Its Autoanalysis Applications software converts your instruments into a digital chart recording system with automatic analysis and reporting features. The PGA-710B will perform measurement and recording functions, perform data analysis, generate charts, then construct and print out complete reports, including the facility’s ambient temperature and relative humidity during each test.

The PGA-710B can be used as a freestanding data logger or recorder for later downloading to your computer. It will communicate with your computer via USB or RS-232 COM port.

The PGA-710B’s unique software will instantly perform mathematical and statistical functions to assist ESD Program Managers and Plant Auditors in defining strengths and weaknesses of the ESDS device transport and handling process. The PGA-710B will calculate the 3-Sigma ranges of Walking and Standing body voltages in your facility, graphically plot the percent probability of equaling or exceeding specific body voltages in the process, and calculate the maximum, minimum and average of voltage generation or decay times.

The PFK-100 set includes our unique PFM-711B Dual Range Field MeterCPM-720B Charged Plate Monitor assembly and PCS-730B ±1 kv Charging Source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.

The battery operated PFM-711B Field Meter is a compact “electronic chopper” design with accuracy of +/- 2% at ambient conditions (23ºC and 30%Rh). It features automatic polarity, measurement “hold” button, low battery indicator, high and low ranges, distance ranging lights for accurate and repeatable measurements, manual zero control and a ground snap. With the supplied analog output cable, it can be used in conjunction with an X-Y plotter or any analog data-recording device.

The CPM-720B Charge Plate Assembly is 3.25 inches square. It attaches to the PFM-711A field meter that can be used for compliance verification testing of ionizers per ESD TR53 or ANSI/ESD SP3.3.

The PCS-730B +/- 1 kV Charging Source is used to charge the CPM-720A to +/- 1,000 volts to measure ionizer decay and material decay. These three instruments are match calibrated to work together for accurate and efficient auditing.

The PGA-710B is a unique electrostatic data analysis device for use with the PFK-100 Fieldmeter/Charge Plate Monitor Set. It records, plots, analyzes and automatically constructs reports of body voltage generation, electrostatic decay, voltage retention, ionizer performance and other static measuring functions. Its analytical features document and automatically calculate projected levels of typical Human Body (HBM) voltages. It helps determine the risk of equaling or exceeding damaging or hazardous HBM discharge voltages in static sensitive facilities.

The Autoanalyzer links to a Field meter’s analog output and lap top computer’s USB using provided cables. Its Autoanalysis Applications software converts your instruments into a digital chart recording system with automatic analysis and reporting features. The PGA-710B will perform measurement and recording functions, perform data analysis, generate charts, then construct and print out complete reports, including the facility’s ambient temperature and relative humidity during each test.

The PGA-710B can be used as a freestanding data logger or recorder for later downloading to your computer. It will communicate with your computer via USB or RS-232 COM port.

The PGA-710B’s unique software will instantly perform mathematical and statistical functions to assist ESD Program Managers and Plant Auditors in defining strengths and weaknesses of the ESDS device transport and handling process. The PGA-710B will calculate the 3-Sigma ranges of Walking and Standing body voltages in your facility, graphically plot the percent probability of equaling or exceeding specific body voltages in the process, and calculate the maximum, minimum and average of voltage generation or decay times.

The PFK-100 set includes our unique PFM-711B Dual Range Field MeterCPM-720B Charged Plate Monitor assembly and PCS-730B ±1 kv Charging Source. With this instrument set you can measure electrostatic fields, analyze ionizer performance and assess the voltage generation of materials, equipment and personnel.

The battery operated PFM-711B Field Meter is a compact “electronic chopper” design with accuracy of +/- 2% at ambient conditions (23ºC and 30%Rh). It features automatic polarity, measurement “hold” button, low battery indicator, high and low ranges, distance ranging lights for accurate and repeatable measurements, manual zero control and a ground snap. With the supplied analog output cable, it can be used in conjunction with an X-Y plotter or any analog data-recording device.

The CPM-720B Charge Plate Assembly is 3.25 inches square. It attaches to the PFM-711A field meter that can be used for compliance verification testing of ionizers per ESD TR53 or ANSI/ESD SP3.3.

The PCS-730B +/- 1 kV Charging Source is used to charge the CPM-720A to +/- 1,000 volts to measure ionizer decay and material decay. These three instruments are match calibrated to work together for accurate and efficient auditing.

What's Included?

Measure, record, analyze and report electrostatic voltage generation and decay performance

  • Analyze Footwear & Flooring Combinations: Records personnel walking voltages in accordance with ANSI/ESD STM 97.2 Body Voltage measurements as required by ANSI/ESD S 20.20 ESD Program Standard
  • Test & Audit Ionizers: Records and analyses ionization offset and decay time in accordance with ANSI/ESD SP 3.3 and ANSI/ESD STM 3.1 and generates performance reports
  • Other Equipment Applications include voltage generation of chairs, carts and process equipment
  • Records voltage data at 50, 100 or 200 samples per second
  • File recording time at 50 samples/second is 14 minutes
  • Has internal memory for remote data recording, allows downloading at a later time
  • Operates on its own rechargeable battery, which recharges from your computer or supplied AC/DC charger
  • Accepts up to 2.0 volts from any instrument analog output

Measure fields and voltage generation and balance ionizers

  • Measure range & polarity of electrostatic fields in 1 volt or 10 volts increments
  • Charges from zero to over 1000 volts in less than 10 seconds
  • Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification
  • Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.
  • Measure Body Voltage Generation and Decay
  • Use with a datalogger to record measurements & create reports
  • Compatible with the Autoanalysis System
  • Accuracy of ± 5%
  • Battery Operated

A helping hand for ionizer analysis!

  • Holds 3 instruments
  • Lightweight
  • Aluminum

Determine temperature and humidity

  • Simultaneous display of %RH, Temperature and Dew point or Wet Bulb or Probe Temperature
  • Wet bulb measurements without slinging
  • Calculates T1-T2 differential (Air Temperature-External Probe Temperature) using optional probe
  • Unique sensor cap design twists to closed position for protection during storage
  • Switchable °F/°C temperature units with 0.1° resolution
  • Data Hold freezes current reading on display
  • Max/Min readings
  • Auto Power off to save battery life
  • Complete with 2 AAA batteries

Designed for durability, lightweight portability and comfort

  • Comfortable & Operator Friendly
  • Includes a 12 foot cord with 1 Megohm Resistor
  • Adjustable buckle with a 4mm snap
  • Built-in 10mm male snap with cap
  • Uses 1/3 the working or storage space
  • Metal Alligator Clip included
  • One size fits all
  • Meets the requirements of ANSI/ESD S20.20 and ANSI/ESD S1.1

Triple receptacle grounding cube provides an ESD ground path to a previously tested electrical outlet for up to three ground circuits

  • Recommended for use on tested electrical outlets
  • Replaces expensive grounding blocks and circuit indicators
  • Convenient connection for ESD grounding
  • Comes in several grounding configurations
  • Use with an ESD wrist strap and ground cord for work surface grounding
  • Provides ESD grounding anywhere
  • Made from Non-flammable materials
  • Three ESD ground connection jacks on each Cube

Black Molded Carrying Case for Ionization Kit

  • Molded Carrying Case
  • Foam Insert for protection of equipment
  • Includes Accessory Box

Black Accessory Case for Carrying Case

  • Ballistic nylon construction is lightweight and durable
  • Zipper closure secures accessories and offers easy access
  • Attached hand strap for ease of carry
  • Designed to fit in most Prostat Carrying Cases
  • Color: Black

Measure, record, analyze and report electrostatic voltage generation and decay performance

  • Analyze Footwear & Flooring Combinations: Records personnel walking voltages in accordance with ANSI/ESD STM 97.2 Body Voltage measurements as required by ANSI/ESD S 20.20 ESD Program Standard
  • Test & Audit Ionizers: Records and analyses ionization offset and decay time in accordance with ANSI/ESD SP 3.3 and ANSI/ESD STM 3.1 and generates performance reports
  • Other Equipment Applications include voltage generation of chairs, carts and process equipment
  • Records voltage data at 50, 100 or 200 samples per second
  • File recording time at 50 samples/second is 14 minutes
  • Has internal memory for remote data recording, allows downloading at a later time
  • Operates on its own rechargeable battery, which recharges from your computer or supplied AC/DC charger
  • Accepts up to 2.0 volts from any instrument analog output

Measure fields and voltage generation and balance ionizers

  • Measure range & polarity of electrostatic fields in 1 volt or 10 volts increments
  • Charges from zero to over 1000 volts in less than 10 seconds
  • Balance Ionizers per ANSI/ESD SP3.3 Periodic Verification
  • Measure Ionizer Decay time as per ANSI/ESD S3.1 and ANSI/ESD SP3.3.
  • Measure Body Voltage Generation and Decay
  • Use with a datalogger to record measurements & create reports
  • Compatible with the Autoanalysis System
  • Accuracy of ± 5%
  • Battery Operated

A helping hand for ionizer analysis!

  • Holds 3 instruments
  • Lightweight
  • Aluminum

Determine temperature and humidity

  • Simultaneous display of %RH, Temperature and Dew point or Wet Bulb or Probe Temperature
  • Wet bulb measurements without slinging
  • Calculates T1-T2 differential (Air Temperature-External Probe Temperature) using optional probe
  • Unique sensor cap design twists to closed position for protection during storage
  • Switchable °F/°C temperature units with 0.1° resolution
  • Data Hold freezes current reading on display
  • Max/Min readings
  • Auto Power off to save battery life
  • Complete with 2 AAA batteries

Designed for durability, lightweight portability and comfort

  • Comfortable & Operator Friendly
  • Includes a 12 foot cord with 1 Megohm Resistor
  • Adjustable buckle with a 4mm snap
  • Built-in 10mm male snap with cap
  • Uses 1/3 the working or storage space
  • Metal Alligator Clip included
  • One size fits all
  • Meets the requirements of ANSI/ESD S20.20 and ANSI/ESD S1.1

Triple receptacle grounding cube provides an ESD ground path to a previously tested electrical outlet for up to three ground circuits

  • Recommended for use on tested electrical outlets
  • Replaces expensive grounding blocks and circuit indicators
  • Convenient connection for ESD grounding
  • Comes in several grounding configurations
  • Use with an ESD wrist strap and ground cord for work surface grounding
  • Provides ESD grounding anywhere
  • Made from Non-flammable materials
  • Three ESD ground connection jacks on each Cube

Black Molded Carrying Case for Ionization Kit

  • Molded Carrying Case
  • Foam Insert for protection of equipment
  • Includes Accessory Box

Black Accessory Case for Carrying Case

  • Ballistic nylon construction is lightweight and durable
  • Zipper closure secures accessories and offers easy access
  • Attached hand strap for ease of carry
  • Designed to fit in most Prostat Carrying Cases
  • Color: Black
  • Certificates of Calibration with data, traceable to NIST
  • User Manual

How to Use

Get in Touch

The form below will help us better understand your needs and get you as quickly as possible to the right person. We look forward to helping you solve your static problem! 

You can expect a response within 24 hours. For faster service, please give us a call: 617-923-2000

Visit our privacy policy to find out how we process data.

Twitter
LinkedIn
Facebook
Reddit
Pinterest
Email
Background graphic is a still from the StaticWorx GroundSafe ESD Flooring – Your Trusted Partner explainer animation. In the foreground at the bottom are two boxes. The top is a bright blue with the StaticWorx logo and "GroundSafe ESD Flooring" underneath in white. The second is a dark blue-gray and includes the text in white: “GroundWorx ESD Flooring – Your Trusted Partner”
Play Video

StaticWorx high-performance static-control floors protect electronic components, explosives, and high-speed computers from damage caused by static electricity. ESD flooring is part of a system. Choices should always be based on objective, researched evidence. When you partner with us, we look at all possible items that may need to integrate with the floor, and, focusing on your goals and objectives, help you find the right floor for your application.